CLOG DETECTOR

Tecnical characteristics

Technical Feature Value / Detail
Dimensions 152 x 76 x 15 mm
Measuring range 0-25 mm H₂O, sensitivity 5 mm per 1 mm H₂O
Maximum operating temperature from -30° C to +60° C
Optimal operating temperature from +5° C to +30° C
Maximum static pressure 6 bar
Manometer body Transparent Altuglas®, 15 mm thick
Liquid column Entirely bored into the mass (0.4 mm dia.)
Graduation Silk-screened on the back with different color zones:
– white, from 0 – 5 mm H₂O
– green, from 5 – 10 mm H₂O
– yellow, from 10 – 15 mm H₂O
– red, from 15 – 25 mm H₂O
Manometric liquid AWS 10 RED oil – density 0.87 at 15°C
Reserve capacity 20 ml
Fittings Semi-rigid transparent tube 5 x 8 mm dia., on knurled nickel-plated brass fittings 6.2 mm dia., 1/8 gas thread

DESCRIPTION

Inclined liquid column manometers (AIR PRESSURE SENTINEL® series) are used for measuring small variations in pressure, vacuum, or differential pressure of air or gas. The Air Pressure Sentinel 25 has been specifically designed to monitor filter clogging in spray booths.

Would you like to request more information about our products?